Quietside Dual Purpose Water Heater
Quietside DPHS units that Nottawasaga Mechanical provides are Gas fired Dual Purpose Hydronic Heating units capable of providing space heating in addition to “On Demand” DHW supply. All units are sealed combustion operation and “Energy Star" approved.
QVM9 Series Wall Hung Dual Purpose Water Heater
Quietside QVM9 series wall hung gas dual purpose water heater is Energy Star approved for heating and domestic hot water, 90% efficiency and available in different capacities. Features sealed combustion and venting with schedule 40 PVC. Domestic hot water is provided on demand and has priority over the heating demand.
|
Product Name |
Description |
Heating Input (Btu/h) |
|
|
90% Wall Hung DPHS (90K) |
46,000-90,000 |
|
|
90% Wall Hung DPHS (115K) |
55,000-115,000 |
|
|
90% Wall Hung DPHS (135K) |
65,000-135,000 |
|
QVM9-090W1-NG |
|
|
90% Wall Hung DPHS 90 000 |
Specifications
Heating System Data
|
Heating Input (Btu/h) |
46,000-90,000 |
|
AFUE(%) |
90 |
|
Temperature Range (DegF) |
104-176 |
|
Working Pressure(psi) |
15 |
|
Freeze Protection Device |
Thermistor |
|
Heating Min Flow(GPM) |
1.06 |
|
Heating Exch Water Vol(Gal) |
0.18 |
|
Ignition Type |
Electronic Spark |
Domestic Hot Water
|
Temperature Setting |
Not Controlled |
|
GPM at 50F in 100F Out |
3.2 |
|
GPM at 50F in 110F Out |
2.6 |
|
GPM at 50F in 120F Out |
2.3 |
|
GPM at 50F In 130F Out |
2 |
General Data
|
Fuel Type |
NG or LP |
|
NG Inlet Press('wc) |
5.82-9,7 |
|
Gas Line Size(inch) |
Min Size 3/4 |
|
Unit Voltage(V) |
115V-1Ph-60Hz |
|
Power Consumption(W) |
120 |
|
Breaker Size(A) |
15 |
|
NOX Levels(ppm) |
20 |
|
Max Flue Temp(DegF) |
185 |
|
Max Vent Length(Feet) |
31 Ft Equivalent |
|
Max Number of Elbows |
3 per vent
Dimensions |
|
Weight(lbs) |
75 |
|
Height(less vent Conns)x Width x Depth(inch) |
27 3/8 x 19 1/2 x 8 1/2 |
|
Gas Connection Dia(Inch) |
1/2 |
|
Heating Supply/Return(Inch) |
3/4 |
|
DHW Inlet / Outlet (inch) |
1/2 |
|
Flue / Air Intake(inch) |
Adaptor 3.5 |
|
QVM9-125W1-NG |
|
|
90% Wall Hung DPHS 115 000 |
Specifications
Heating System Data
|
Heating Input (Btu/h) |
55,000-90,000 |
|
AFUE(%) |
90 |
|
Temperature Range (DegF) |
104-176 |
|
Working Pressure(psi) |
15 |
|
Freeze Protection Device |
Thermistor |
|
Heating Min Flow(GPM) |
1.06 |
|
Heating Exch Water Vol(Gal) |
0.18 |
|
Ignition Type |
Electronic Spark |
Domestic Hot Water
|
Temperature Setting |
Not Controlled |
|
GPM at 50F in 100F Out |
4.0 |
|
GPM at 50F in 110F Out |
3.3 |
|
GPM at 50F in 120F Out |
2.9 |
|
GPM at 50F In 130F Out |
2.6 |
General Data
|
Fuel Type |
NG or LP |
|
NG Inlet Press('wc) |
5.82-9,7 |
|
Gas Line Size(inch) |
Min Size 3/4 |
|
Unit Voltage(V) |
115V-1Ph-60Hz |
|
Power Consumption(W) |
140 |
|
Breaker Size(A) |
15 |
|
NOX Levels(ppm) |
20 |
|
Max Flue Temp(DegF) |
185 |
|
Max Vent Length(Feet) |
31 Ft Equivalent |
|
Max Number of Elbows |
3 per vent
Dimensions |
|
Weight(lbs) |
79 |
|
Height(less vent Conns)x Width x Depth(inch) |
27 3/8 x 19 1/2 x 8 1/2 |
|
Gas Connection Dia(Inch) |
1/2 |
|
Heating Supply/Return(Inch) |
3/4 |
|
DHW Inlet / Outlet (inch) |
1/2 |
|
Flue / Air Intake(inch) |
Adaptor 3.5 |
|
QVM9-150W1-NG |
|
|
90% Wall Hung DPHS 135 000 |
Heating System Data
| Heating Input (Btu/h) |
65,000-135,000 |
| AFUE(%) |
90 |
| Temperature Range (DegF) |
104-176 |
| Working Pressure(psi) |
15 |
| Freeze Protection Device |
Thermistor |
| Heating Min Flow(GPM) |
1.06 |
| Heating Exch Water Vol(Gal) |
0.21 |
| Ignition Type |
Electronic Spark |
Domestic Hot Water
| Temperature Setting |
Not Controlled |
| GPM at 50F in 100F Out |
4.9 |
| GPM at 50F in 110F Out |
4.0 |
| GPM at 50F in 120F Out |
3.4 |
| GPM at 50F In 130F Out |
3 |
General Data
| Fuel Type |
NG or LP |
| NG Inlet Press('wc) |
5.82-9,7 |
| Gas Line Size(inch) |
Min Size 3/4 |
| Unit Voltage(V) |
115V-1Ph-60Hz |
| Power Consumption(W) |
160 |
| Breaker Size(A) |
15 |
| NOX Levels(ppm) |
20 |
| Max Flue Temp(DegF) |
185 |
| Max Vent Length(Feet) |
31 Ft Equivalent |
| Max Number of Elbows |
3 per vent
Dimensions |
| Weight(lbs) |
84 |
| Height(less vent Conns)x Width x Depth(inch) |
28 1/8 x 20 1/4 x 9 5/8 |
| Gas Connection Dia(Inch) |
1/2 |
| Heating Supply/Return(Inch) |
3/4 |
| DHW Inlet / Outlet (inch) |
1/2 |
| Flue / Air Intake(inch) |
Adaptor 3.5 |
|
|